Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine

Product Details
Customization: Available
Type: Microneedle
Theory: RF Fractional
Still deciding? Get samples of US$ 1380/Piece
Request Sample
Manufacturer/Factory, Group Corporation

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
101~500 square meters
Management System Certification
ISO 9001, ISO 13485
  • Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine
  • Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine
  • Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine
  • Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine
  • Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine
  • Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine
Find Similar Products
  • Overview
  • Product Description
  • After Sales Service
  • Company Profile
  • Certifications
  • Exhibition
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
GMS-H4
Application
Salon, Home
Portable
Portable
Handles
2 PCS 1. Microneedle Handle, 2. Cold&Hot Handle
RF Frequency
2MHz- 4MHz
RF Power
10-150W
Tip Pins
10pin, 25pin, 64pin, Nnano
Needle Thickness
0.3mm
Needle Depth
0.2-3.5mm(0.1step)
Treatment Duration
0.1~0.6s
Cool Temperature Range
-10 to -5 to 0
Hot Temperature Range
0 to 36 to 40
Suction Level
2 Level
Control Display
8.4inch Color Touch Screen
Transport Package
Aviation Aluminum Box
Specification
58*46*52.5cm
Trademark
GOMECY
Origin
China
Production Capacity
200PCS/Month

Product Description

Product Description

 CE approved technology newest fractional rf microneedle/microneedling machine

Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine

Product Principle 

The Micro-Needle Fractional RF System is the ideal technology for skin lifting, tightening and rejuvenation by utilising minimally invasive micro-needles to deliver controlled RF energy directly into various depths of the skin.It has had outstanding success for all skin types with a very low risk of side effects and PIH - a key difference when compared to optical based treatments (IPL & Laser).

 

The depth of penetration of the micro-needles can be adjusted from 0.5 to 3.5mm based on treatment target areas with outstanding end results such as skin lifting, pore-size reduction, tightening and overall rejuvenation.

Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine

Applications

Face Treatment

1.Non-surgical Face Lifting

2.Wrinkle Reduction

3.Skin Tightening

4.Skin Rejuvenation (Whitening)

5.Pore Reduction

6.Acne Scars

7.Scars

 

Body Treatment
1.Scars
2.Hyperhidrosis
3.Stretch Marks
4.Spider Veins (Veincure Option)

Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF MachineKorea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine

Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine

 

 

Advangages:

1.treatment with vacuum,more comfertable
2. Non Insulated Needles 
It is possible to operate equal therapy to Epidermis Layer and Dermis Layer as the needle do not have Insulation Plating.
3. Stepping Motor Type
Different to existing Solenoid Type, the needle inserts to the skin smoothly with no shock, and causes no bleeding and no pain after the procedure.
4. Gold Plated Needles
Needle is durable and also has high Biocompatibility by applying Gold Plating. Patient with metal allergy could also use it with not concerning Contact Dermatitis.
5. Precise Depth Control. 0.5~5.0mm [0.1mm Step]
Operates epidermis layer and dermis layer by Controlling the needle depth in unit of 0.1mm
6. Safety Needle System
- Sterilized disposable needle tip
- Operator can easily notice the applying RF energy from ared light.
7. Elaborate Needle Thickness. Min : 0mm < Max : 0.3mm
The needle structure is easy to penetrate the skin with minimum resistance

 

Machine details:

 Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine

 

Specifications

  RF frequency   2MHz-4Mhz
  RF power   10-150W
  Needle cartridges   10pin,25pin,64pin and nano needle
  Needle Thickness   0.3mm
  Needle Depth   0.2-3.5mm(0.1 step)
  Treatment Duration   0.1-0.6s
  Suction level   2 level
  Control Display   8.4 inch color touch screen
  Voltage   AC 110V/220V, 50Hz/60Hz
  Weight   15kg

 

Before & After:

Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine

After Sales Service

1. One year warranty, if there any problems happens with your machine, we will repair it free of charge.

2. Convenient training, user manual and operation video are available, also, if it is not enough, we can provide the online face to face education.

3. OEM/ODM services, your logo, outside shape, language, interface can specially be designed on your machine.

4. After sales service, offer 7*24 hours online service, lifetime free maintenance, technology support forever.

5. Products all be assures safe, no broken, and packed with aluminum flight case.

6. Highly recommend by DHL shipping, our company enjoyed VIP shipping service, all we quoted are the favorable price, and goods will arrive your country within 2-4 working days. (Except overweight and oversize products)
Company Profile

Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF MachineKorea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine

Certifications

Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine

Exhibition

Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine

Packaging & Shipping

Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine

FAQ

Korea Stretch Marks Anti-Wrinkle Removal Skin Rejuvenation Fractional RF Machine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier